Click to enlarge image
|
Model Number |
NGA-6000 |
|
 |
|
| Gas Analyzer Features |
|
| |
- Outstanding accuracy, stability and durability |
|
| |
- Upgradeable to five gas (NOx option) |
|
| |
- Response time of less than 10 seconds |
|
| |
- Stand-by for extended pump life and low power consumption |
|
| |
- Automatic adjustment of Warm-up time - 2 ~ 8 minutes |
|
| |
- RS232 PC-Link kit (software & cables) |
|
| |
- Elegant appearance |
|
| |
- Portable (compact size, light weight) |
|
|
- Spare parts kit supplied as standard |
|
|
- 5 Stage filtration system for bench protection |
|
|
- Compatible with Dyno applications |
|
|
- Leak check function to check hose and probe integrity |
|
|
- Hold function to pause measurement |
|
|
- Official Emission Testing Software |
|
|
- Residual HC test |
|
|
- Fuel type selection ? Petrol, LPG, CNG and Alcohol |
|
|
- Stainless steel probe for extended life |
|
|
- Built in Printer |
| |
| |
 |
|
| Measuring Item |
|
CO, HC, CO2, λ (air surplus rate), AFR, NOx (optional) |
|
| Measuring Method |
|
CO, HC, CO2 : NDIR Method |
|
| Measurements |
|
O2, NOx : Electrochemical Cell |
|
| Repeatability |
|
Within 10 seconds (more than 90%) |
|
| Measuring Range |
|
CO |
|
HC |
|
CO21 |
|
O2 |
|
O2 |
|
AFR |
|
Nox |
|
| Resolution |
|
0.00~9.99% |
|
0~9,999 or 20,000ppm |
|
0.0~20.0% |
|
0.00~25.00% |
|
0~2.000 |
|
0.0~99.0 |
|
0~5,000ppm |
|
| Display |
|
0.01% |
|
1ppm |
|
0.10% |
|
0.01% |
|
0.001 |
|
0.1 |
|
1 ppm |
|
| Response Time |
|
"4 Digit 7 Segment LED" |
|
"4 or 5 Digit 7 Segment LED" |
|
"4 Digit 7 Segment LED" |
|
"4 Digit 7 Segment LED" |
|
"4 Digit 7 Segment LED" |
|
"4 Digit 7 Segment LED" |
|
"4 Digit 7 Segment LED" |
|
| Warming |
|
Less than ± 2 % FS |
Power |
|
AC 110V only or AC 220V only ± 10 %, 60Hz |
|
| Pump Flow Rate |
|
2 ~ 8 L/min |
Power Consumption |
|
About 50 W |
|
| Dimensions |
|
4 ~ 6 L/min |
Operating Temperature |
|
0°C ~ 40°C |
|
Basic Accessories
|
|
420 (W) x 298 (D) x 180 (H) mm
|
Weight |
|
About 6.9㎏ |
|
| Basic Accessories |
|
Probe, Sample Hose, Spare Fuse, Leak Test Cap, Spare Filter, Operators Manual, Power Cord, Ground Cable, Calibration Controller Nipple, Calibration Connecting Hose, RS232 Cable, Printer, Printer Paper, PC Program | |
|
|
|
|
| |
|
|
|